Thermo Fisher Scientific Port Devices Driver Download



Home >Software > RheoWin 4.87.0005

The COVID-19 pandemic affected the global food chain from farm to table. It damaged one of the most important sectors of the world economy with problems that are still influencing the industry today. But even before the pandemic began, the FDA had announced its New Era of Smarter Food Safety.

  1. Some Windows NT device drivers (e.g.: network or graphic adaptor driver) already use (too) much memory. (There is a known problem with an STB graphic adaptor driven in true color mode, it can be fixed by switching to 16 bit color.).
  2. Connect the ethernet cable to the ethernet port on the instrument. Connect the ethernet cable to the ethernet port wall plug. In the absence of the ethernet cable or the ethernet port, connect a High-Power USB Wi-Fi Module (Cat. A26774) to the instrument using the USB port on the instrument. USB port for wi-fi.
Thermo Fisher Scientific Port Devices Driver Download

Download the RheoWin files

This is a fully executable version of RheoWin 4.

Note: In order to be able to install RheoWin 4 on your computer you need a RheoWin 4 License Key !

Fisher

Download the following *.ZIP file and copy them to a single (temporary) directory on your hard drive.

  • Download file (File: rhw4870006_complete.zip, 161 Mbyte, from january 18 2021)
  • RheoWin information file (File: RheoWin_Readme.pdf, 3.1 Mb)
  • RheoWin what's new file (File: RheoWin_New.pdf, 0.1 mb)

Then unzip the *.ZIP file using any suitable unzip program.

In case you do not have an (UN)ZIP program you can download a freeware ZIP program from
the following Web-site: http://www.ozemail.com.au/~nulifetv/freezip/index.html.

SHRP element and Asphalt/Bitumen software module

Note:

  • The SHRP evaluation element is now part of the new Asphalt/Bitumen software module and not part of the standard installation anymore. Customers with a valid RheoWin installation key (issued before 01.01.2021) can request a special installation key (order no. 098-5567) for the SHRP evaluation element at no cost.
  • The new Asphalt/Bitumen software module consists of the new MSCR, the new BYET and the new LAS evaluation elements as well as the existing SHRP evaluation element. A special installation key (order no. 098-5566) is needed to install the Asphalt/Bitumen software module.

Updates for version 4.87.0005

There are currently no updates for this version.

RheoWin 4.8x.00xx and Windows XP

Starting from version 4.70.0000 RheoWin has not been tested under Windows XP (in any version) anymore and is therefore not supported for use under Windows XP anymore.


Virtual com port driver for Viscotester D and Viscotester E

The virtual com port driver for the Viscotester D and Viscotester E is available for download here.


Virtual com port driver for SC and AC circulators

The virtual com port driver for the new SC and AC circulators is available for download here.


Updates/Downloads for Foculus camera (RheoScope module)

New FGControl software and drivers for Windows 7, 8, 8.1 and 10 64-bit and 32-bit

For Windows 7, 8, 8.1 and 10 both in the 32-bit and the 64-bit versions the use of the new FGControl software and drivers is obligatory.

  • Download 32-bit software and drivers (File: FGControl_Install_V2602_x86,zip, 13.4 Mb).
  • Download 64-bit driver for Windows 64-bit (File: FGControl_Driver_Win7_64.zip, 107 kb).

Driver for the new USB3 3iCube cameras

  • Download the 3iCube camera driver and documentation (File: 3iCube_Camera_Driver.zip, 6.4 Mb).
Thermo fisher scientific port devices driver download 64-bit

Thermo Fisher Scientific Port Devices Driver Download Torrent


Supported rheometers, viscometers, temperature control systems and other devices

  • RheoWin 4 currently supports the following HAAKE instruments:
    RheometersViscometersCirculatorsTemp.Controllers
    MARS 40SC150, ACxxx, PCxxx**MTMC
    (MARS I, III, 40, 60, iQ, iQ Air)
    MARS 60Viscotester iQ AirUTMC
    MARS iQ Air
    MARS iQ
    MARS IViscotester iQACCEL**
    MARS IIVT550CTC (Oven)
    MARS IIIDynamax
    RheoStress 6000RotoVisco 1UTC
    RheoStress 3000
    RheoStress 600VT D, VT E
    RheoStress 300
    RheoStress 1 *
  • * RheoWin 4 currently does not support the first series of RheoStress 1 instruments, for these instrument only RheoWin 3.x upto version 3.5x can be used.
    The first series of RheoStress 1 instrument can be recognized by the silver coloured drive motor shaft.
    The second series of RheoStress 1 instrument have a dark coloured drive motor shaft.
  • ** A firmware update may be needed for these devices to be compatible with RheoWin,see here.
  • Starting from RheoWin 4.70.0000 the following older instruments are not supported anymore.
    Rheometers: RS150, RS80, RS75, RheoScope 1 and RT20
    Viscometers: VT6L, VT6R, VT7L, VT7R as well as the VT7L-plus and VT7-R-plus
    Thermocontrollers: TC80, TC81, TC500 and TC501
    Circulators: F3C, F6/N6/F8/N8, DC30, DC50 and Phoenix
    For these instruments please use RheoWin 4.63.0004.
  • RheoWin 4 does not support older instruments like the RT10, VT500, VT501 and the RV20+RC20/RV30 with CV20, CV100, M5 or M10. For these instruments please use RheoWin 2.97.
  • RheoWin 4 does not support the RS100 1 Ncm, the RS100 5 Ncm und the RS50.
    For these instruments please useRheoWin 3.61.
  • The new FGControl driver for the (RheoScope) Foculus camera is compatible with
    the 32-bit and 64-bit Windows versions of Windows 7, Windows 8 and Windows 8.1.
  • The older FOControl driver for the Foculus camera is compatible with Windows XP 32-bit only.
  • The driver for the previously used Sony XCD-X710 camera is only compatible
    with RheoWin 4.50.00xx under Windows XP 32-bit.

Supported operating systems

  • RheoWin 4.87.00xx has been tested to run under the following Windows operating systems:
    - Windows 10 (both the 32-bit and the 64-bit version).
    - Windows 8.1 (both the 32-bit and the 64-bit version).
    - Windows 8 (both the 32-bit and the 64-bit version).
    - Windows 7 (both the 32-bit and the 64-bit version).
  • RheoWin 4.87.00xx is currently NOT supported for use under the following operating systems:
    - Windows XP with or without any Service Pack.
    - Windows Vista with or without any Service Pack.
  • RheoWin 4.87.00xx can not be installed and consequently will NOT run and/or is not supported for use
    under the following Microsoft Windows operating systems (or any other operating system)
    - Windows ME
    - Windows 98 SE
    - Windows 98 with Y2K update and Internet Explorer 4.01 SP2
    - Windows 95
    - Windows 3.x
    - Windows NT3.x
    - Windows 2000 with Service Pack 1 (or higher)
    - Windows NT4.0 with Service Pack 6 and Internet Explorer 6
  • We recommend the use of a PC according to the specifications given by Microsoft for the operating system used.

Rheowin 4 license key

In order to be able to install this version of RheoWin on your computer you will need a valid RheoWin 4 license key. A RheoWin 3 or a RheoWin 2 key will not enable you to install RheoWin 4.0.

A separate license key is needed for installing the tools for FDA 21 CFR part 11 compliance. A separate license key is also needed to install the TTS (Time Temperature Superposition), Spectra and MWD (Molecular Weight Distribution) tools as well as for the installation of some other optional software features.

The keys for RheoWin 4 consist of a company name, serial number and the key code. When you receive the key per e-mail this information will be stored in a *.key or *.txt file which can be opened and viewed by using any text-editor (Notepad, Write, Word, etc.).

The key information must either be entered manually (as in previous versions) or loaded from the supplied *.txt file (this is new for version 4.40) during the installation process.

A Key-Diskette for RheoWin 2.x or a RheoWin 3.x key will NOT enable you to install RheoWin 3, however the upgrade from RheoWin 2 or RheoWin 3 to RheoWin 4 is free of charge (shipping and handling costs may apply).

In order to request a RheoWin 4 license key download the RheoWin Key order form fill it out as completely as possibly, save it and send it to support.mc.de[at]thermofisher.com (replace [at] by @). You will then receive your new key per e-mail.


Installation of RheoWin 4

RheoWin 4 can be installed parallel to an existing RheoWin 2.xx and/or RheoWin 3.xx installation if needed. Please note that RheoWin 4 can read RheoWin 2.xx and 3.xx data, job and page files (backward compatibility), but that older RheoWin version can not read files saved by newer versions!! RheoWin 2.xx, 3.xx and 4.xx should ALWAYS be installed in different directories.

RheoWin 4.87.00xx can be installed, as an Upgrade installation, over an existing RheoWin 4.20.00xx, RheoWin 4.30.00xx, RheoWin 4.4x.00xx and RheoWin 4.50.00xx version, without deinstalling the older version first. In this case the settings from the previous installation are automatically used for the new version.

Here's how to install RheoWin:

  1. Please read the document new.doc BEFORE installing RheoWin 4!
  2. Please note that (Windows) Administrator rights are needed to install RheoWin!
  3. Upgrade installation:
    In case the settings of the previous installation should be used used for the new
    installation the previous version must not be deinstalled before the new version is installed.
    Please note: The 'upgrade installation' can only be used for an existing
    RheoWin 4.20.00xx, RheoWin 4.30.00xx or RheoWin 4.4x.00xx installation!
    Please note: For older RheoWin versions (version 4.10.00xx and older) the 'Upgrade
    installation
    ' method can not be used, that means that the 'New installation' method
    (see 3b below) must be used, in this case the settings of the previous installation
    will not be available in the new installation.
    New installation:
    Deinstall (remove) any previous RheoWin 4 version first (if applicable):
    Click the Windows Start button, then select Settings, then select Control Panel,
    in the Control Panel select Add or Remove Programs, in the list of programs select
    HAAKE RheoWin and then click on the Change/Remove button and follow the instructions.
    Please note: In this case the settings from a previous installation will be lost and can
    not be automatically used for the subsequent new installation!
  4. Starting the installation program from a directory on your harddisk in which you unzipped the *.ZIP file :
    To install RheoWin from harddisk go to the (temporary) directory in which
    you unzipped the *.ZIP file after downloading. Please make sure that you
    have the following file in that directory: Setup.exe
    To start the installation please run the Setup.exe program.
    Starting the installation program from the RheoWin CD :
    This CD is 'self-starting', just click on 'Install HAAKE RheoWin 4' to start the installation.
    In case the installation screen does not come up automatically you can start it by
    double-clicking on the file 'index.htm' in the Windows explorer, this will show the
    installation screen in your web-browser.
    You can also start the installation by run the setup.exe program from the RheoWin
    directory on the CD

The installation program will guide you through the installation. Please make sure that you have a RheoWin 4 License Key (see above) readily available since the installation program will ask for this.

For a detailed and complete description of the RheoWin installation see the HAAKE RheoWin Installation and 21 CFR part 11 configuration User Guide, which is available on the RheoWin CD and can be downloaded using the following links:

  • Download HAAKE RheoWin User Guide Installation and 21 CFR part 11
    (File: RheoWin_Installation+21CFRP11_E.pdf, 2.3 Mb).
  • Download HAAKE RheoWin Benutzer Handbuch Installation und 21 CFR part 11 Konfiguration
    (File: RheoWin_Installation+21CFRP11_D.pdf, 2.5 Mb).

Home >Software > RheoWin 4.30.00xx

Download the RheoWin files

This is a fully executableversion of RheoWin 4. Please note that in order to be able to install RheoWin 4 on your computer you need a RheoWin 4 License Key !

Download the following *.ZIP file and copy them to a single (temporary) directory on your hard drive.

  • Download file (File: rhw430030_complete.zip, 87 Mbyte, from July 31 2013).
  • RheoWin information file (File: rhw430030_readme.doc, 164 kbyte)
  • RheoWin what's new file (File: rhw430030_new, 44 kbyte)

Then unzip the *.ZIP file using any suitable unzip program.

In case you do not have an (UN)ZIP program you can download a freeware ZIP program from the following Web-site : http://www.ozemail.com.au/~nulifetv/freezip/index.html.


Updates

There are no updates available for this version.


RheoWin 4 and Windows 7 and Windows 8

RheoWin 4 is compatible with Windows 7 and Windows Vista (both the 32 bit and 64 bit versions).
RheoWin 4 is also compatible with Windows 8 (until now we have only tested the 32-bit version).

Please note: Currently the driver for the Foculus camera, which is used with the RheoScope module is NOT compatible with Windows Vista 64 bit, Windows 7 64 bit and Windows 8 64 bit.


Virtual com port driver for Viscotester D and Viscotester E

The virtual com port driver for the Viscotester D and Viscotester E is available for download here.


Virtual com port driver for SC and AC circulators

The virtual com port driver for the new SC and AC circulators is available for download here.


Update for Foculus camera (RheoScope module)

In case you do not get an image from the FOculus camera which comes with the RheoScope module in RheoWin, please download and install the newest driver for this camera from the camera manufacturers web-site using the link below.
Due to a Windows Update (from Microsoft) the Direct X support of the camera driver didn’t work anymore. This was fixed by the manufacturer with a new driver version.

  • Download driver (File: FOcontrol_Install_4.0.5.1.zip, 7.6 Mb).

Please note: Currently the driver for the FOculus camera is NOT compatible with Windows Vista 64 bit and Windows 7 64 bit. The camera manufacturer is working on a solution for this.


Supported instruments

  • RheoWin 4 currently supports the following HAAKE instruments:
    RheometersViscometersCirculatorsTemp.Controllers
    MARS IIVT550DC5TC80
    MARS III
    RheoStress 6000F6, N6TC81
    RheoStress 3000RotoVisco 1F8, N8TC500
    RheoStress 600DC30, DC50TC501
    RheoStress 300VT6L, VT6R, VT7L, VT7RF3CTP1800
    RS150VT7L-plus, VT7R-plusPhoenixUTC
    RS80CTC (Oven)
    RS75VT D, VT EDynamax
    RT20MTMC (MARS III)
    RheoStress 1 *SC150, ACxxx, PCxxx**UTMC
    RheoScope 1ACCEL**
  • * RheoWin 4 currently does not support the first series of RheoStress 1 instruments, for these instrument only RheoWin 3.x upto version 3.5x can be used.
    The first series of RheoStress 1 instrument can be recognized by the silver coloured drive motor shaft.
    The second series of RheoStress 1 instrument have a dark coloured drive motor shaft.
  • ** A firmware update may be needed for these devices to be compatible with RheoWin, see here.
  • RheoWin 4 does not support older instruments like the RT10, VT500, VT501 and the RV20+RC20/RV30 with CV20, CV100, M5 or M10. For these instruments please use RheoWin 2.97.
  • RheoWin 4 also does not support the RS100 1 Ncm, the RS100 5 Ncm und the RS50.
    For these instruments please use RheoWin 3.61.

Thermo Fisher Scientific Port Devices Driver Download

Thermo Fisher Scientific Port Devices Driver Download Windows 7

Supported operating systems

  • We recommend the use of one of the following Microsoft Windows operating systems:
    - Windows 8 (we have only tested 32-bit until now).
    - Windows 7 (both the 32-bit and the 64-bit version).
    - Windows Vista with or without any Service Pack.
    - Windows XP with or without any Service Pack.
    - Windows 2000 with Service Pack 1 (or higher)
  • RheoWin also runs under one of the following Microsoft Windows operating systems, however please note that Microsoft does not supply support for these operating systems anymore!
    - Windows NT4.0 with Service Pack 6 and Internet Explorer 6
  • RheoWin will not run under the following Microsoft Windows operating systems (or any other operating system)
    - Windows ME
    - Windows 98 SE
    - Windows 98 with Y2K update and Internet Explorer 4.01 SP2
    - Windows 95
    - Windows 3.x
    - Windows NT3.x !
  • IMPORTANT: In order to be able to make RheoWin compliant with the FDA 21 CFR part 11 it is required that RheoWin runs under Windows7, Windows Vista, Windows XP or Windows 2000 (or Windows NT 4.0 with the above mentioned restrictions).
  • We highly recommends the use of a PC with a Pentium IV (or faster) processor and at least 512 Mb of RAM.

Thermo Fisher Scientific Port Devices Driver Download Pc


Rheowin 4 license key

In order to be able to install this version of RheoWin on your computer you will need a RheoWin 4 License Key. A Key-Diskette for RheoWin 2.xx or a RheoWin 3 License Key will NOT enable you to install RheoWin 4.

The keys for RheoWin 4 consist of a company name, serial number and the key code. You will have to enter this information manually during the installation. When you receive the key per e-mail this information will be stored in a *.key or *.txt file which can be opened and viewed by using any text-editor (Notepad, Write, Word, etc.)

A separate license key is needed for installing the tools for FDA 21 CFR part 11 compliance. A separate license key is also needed to install the TTS (Time Temperature Superposition) tool, the Spectra calculation tool and the MWD tool.

License Keys for RheoWin 4 are available on request only !

In order to request a RheoWin 4 license key download the RheoWin Key order form fill it out as completely as possibly, save it and send it to support.mc.de[at]thermofisher.com (replace [at] by @). You will then receive your new key per e-mail.


Installation of RheoWin 4

RheoWin 4 can be installed parallel to an existing RheoWin 2.xx installation and/or an existing RheoWin 3.xx installation if needed. Please note that RheoWin 4 can read RheoWin 2.xx and RheoWin 3.xx data, job and page files (backward compatibility), but that RheoWin 2.xx can NOT read RheoWin 3 files and that RheoWin 3.xx can NOT read RheoWin 4 files!!
RheoWin 4 should never be installed in the same directory as RheoWin 2.xx or RheoWin 3.xx!!

The installation program of RheoWin 4 offers the user the possibility to transfer all settings (apart from the Unit settings) from a previous installation of RheoWin 3.xx.

Here's how to install RheoWin:

  1. Please note that (Windows) Administrator rights are needed to install RheoWin!
  2. From a directory on your harddisk in which you unzipped the *.ZIP files:
    To install RheoWin from harddisk go to the (temporary) directory in which you unzipped the *.ZIP files after downloading. Please make sure that you have the following 7 files in that directory : HAAKE RheoWin.msi, Setup.exe, Data1.cab, 1031.mst, 1033.mst, 1034.mst, 1036.mst, 1043.mst. To start the installation please run the Setup.exe program.
  3. From the RheoWin CD:
    This CD is 'self-starting', just click on 'Install HAAKE RheoWin 4' to start the installation. In case the installation screen does not come up automatically you can start it by double-clicking on the file 'index.htm' in the Windows explorer, this will show the installation screen in your web-browser. You can also start the installation by run the setup.exe program from the RheoWin directory on the CD

The installation program will guide you through the installation. Please make sure that you have a RheoWin 4 License Key (see above) readily available since the installation program will ask for this.


Scientific

RheoWin and Windows users (Administrators, PowerUsers, Users, etc.)

Windows users with the default Administratoror PowerUser rights will be able to run RheoWin without the need for any modifications.

For Windows users with the default Users rights an Administrator has to make sure that those users have read access to the RheoWin 4 main directory (by default c:Program FilesThermoRheoWin) and all its subdirectories, as well as read and write (!) access to the
HKEY_USERS.DEFAULTSoftwareThermoRheoWin
key in the windows registry and the following two directories and all their subdirectories
C:Documents and SettingsAll UsersApplication DataThermoRheoWin
C:Documents and SettingsAll UsersDocumentsThermoRheoWin.
Microsoft advices programmers to save application and user data in the above metnioned directories by default, but strange enough does not give Windows users with the default Users rights write access to these directories!